# Pedestrian Wind Comfort, UTCI and Solar Simulation · infrared.city

> Pedestrian wind comfort (Lawson, NEN 8100, Davenport, VDI 3787), thermal comfort (UTCI), solar, sun hours and daylight, for a site or a whole city.

Source: https://infrared.city/products-simulations

Every model the engine runs: what it answers, what it needs and what it returns.

[Try the models in the playground](https://platform.infrared.city/sdk/playground)

How does this compare with ENVI-met, SOLWEIG or PALM-4U? See [when to use which tool](https://infrared.city/products-compare).

**12 models** Wind, perceived heat, sun, daylight and interior.

**0.1 to 1 m grid** A value every 0.1 to 1 m, from rooms to cities.

**One interface** Platform, plugins and API run the same models.

| Model | What it shows | Output | Aligned with |
| --- | --- | --- | --- |
| Wind |  |  |  |
| Wind Speed | Airflow around buildings | m/s | VDI 3787-4 |
| Pedestrian Wind Comfort | Suitability for outdoor activities | Comfort class | Lawson (LDDC), NEN 8100, VDI 3787-4 |
| Heat and comfort |  |  |  |
| Thermal Comfort | Time in comfortable conditions | % of time | UTCI, Bröde et al. 2012, VDI 3787-2, VDI 3785-1 |
| Heat Stress | Occurrence of outdoor heat stress | % of time | UTCI, Bröde et al. 2012, VDI 3787-2 |
| Cold Stress | Occurrence of outdoor cold stress | % of time | UTCI, Bröde et al. 2012, VDI 3787-2 |
| Microclimate (UTCI) | Perceived heat (UTCI) | UTCI · °C | UTCI, Bröde et al. 2012, VDI 3787-2, VDI 3787-8 |
| Sun and light |  |  |  |
| Daylight Availability | Direct-sun availability | 0–100% score | Perez all-weather sky, EN 17037 |
| Sky View Factors | Open sky and enclosure | % visible sky | VDI 3787-1 |
| Direct Sun Hours | Duration of direct sunlight | Hours | EN 17037 sunlight exposure |
| Solar Radiation | Solar energy reaching surfaces | kWh/m² | ISO 52010-1, VDI 3789-2, Perez all-weather sky |
| Interior |  |  |  |
| Interior Daylight Factor | Diffuse daylight inside rooms | Daylight factor · % | CIE standard sky (ISO 15469), EN 17037 |
| Energy Balance | Heating and cooling energy need | kWh/m²·yr | ISO 13790 hourly (Annex C) and monthly methods, EN 15265 test cases, ASHRAE 140 (BESTEST), ISO 6946, ISO 13370 |

[How each model was checked: read the validation notes](https://infrared.city/products-validation)

## Wind around buildings

Airflow, gusts and comfort at pedestrian height.

![Wind Speed: Hong Kong · wind speed · fixed 0–10 m/s scale](https://infrared.city/assets/models/wind-speed-contrast-v4.webp)

### Wind Speed

Where will buildings accelerate wind, and where will they create shelter?

**≈ 0.6 m/s** Between buildings **≈ 5.2 m/s** Open park area

0 m/s 10 m/s

Hong Kong · wind speed · fixed 0–10 m/s scale

Inputs

Building geometry, reference wind speed and wind direction.

Output

Wind speed in m/s across an outdoor ground grid.

Results on

Ground Facades (no) Roofs (no) Rooms (no)

Method

AI model trained on CFD

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-wind-comfort-model-card.pdf)

![Pedestrian Wind Comfort: Hong Kong · annual wind comfort · Lawson 2001](https://infrared.city/assets/models/pedestrian-wind-comfort-contrast-v4.webp)

### Pedestrian Wind Comfort

Which places support sitting, standing or walking through the year?

**Class A** Between buildings **Class D** Open park area

A B C D E S15 S20

Comfort classes A–E; S15/S20 mark safety thresholds. Hong Kong · annual wind comfort · Lawson 2001

Inputs

Building geometry, a weather file with hourly wind speed and direction, and a comfort criterion.

Output

Outdoor comfort categories on a ground grid.

Results on

Ground Facades (no) Roofs (no) Rooms (no)

Method

Lawson, NEN 8100, Davenport, VDI 3787

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-wind-comfort-model-card.pdf)

## Perceived heat (UTCI) and comfort

How hot or cold a place feels, and how often it is comfortable. All four models use the UTCI.

![Thermal Comfort: Hong Kong · share of daytime hours with UTCI 9–26 °C · annual, 09:00–17:00](https://infrared.city/assets/models/thermal-comfort-contrast-v4.webp)

### Thermal Comfort

Which places remain comfortable during the selected period?

**≈ 39%** Open park area **≈ 57%** Between buildings

0% 100%

Hong Kong · share of daytime hours with UTCI 9–26 °C · annual, 09:00–17:00

Inputs

Weather, time period, buildings, trees, shade sails and canopies, and facade, roof and ground materials.

Output

Percentage of selected time in thermal comfort at each ground cell.

Results on

Ground Facades (no) Roofs (no) Rooms (no)

Method

UTCI, comfort band 9 to 26 °C

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-thermal-comfort-model-card.pdf)

![Heat Stress: Hong Kong · share of daytime hours above UTCI 26 °C · annual, 09:00–17:00](https://infrared.city/assets/models/heat-stress-contrast-v4.webp)

### Heat Stress

Where is heat stress recurrent in the selected period?

**≈ 38%** Between buildings **≈ 58%** Open park area

0% 100%

Hong Kong · share of daytime hours above UTCI 26 °C · annual, 09:00–17:00

Inputs

Weather, time period, buildings, trees, shade sails and canopies, and facade, roof and ground materials.

Output

Percentage of selected time in heat stress at each ground cell.

Results on

Ground Facades (no) Roofs (no) Rooms (no)

Method

UTCI above 26 °C

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-thermal-comfort-model-card.pdf)

![Cold Stress: Hong Kong · share of daytime hours below UTCI 9 °C · annual, 09:00–17:00](https://infrared.city/assets/models/cold-stress-contrast-v4.webp)

### Cold Stress

Where is winter discomfort recurrent in the selected period?

**≈ 2%** Open park area **≈ 5%** Between buildings

0% 100%

Hong Kong · share of daytime hours below UTCI 9 °C · annual, 09:00–17:00

Inputs

Weather, time period, buildings, trees, shade sails and canopies, and facade, roof and ground materials.

Output

Percentage of selected time in cold stress at each ground cell.

Results on

Ground Facades (no) Roofs (no) Rooms (no)

Method

UTCI below 9 °C

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-thermal-comfort-model-card.pdf)

![Microclimate (UTCI): Hong Kong · perceived heat (UTCI)](https://infrared.city/assets/models/microclimate-magma-v1.webp)

### Microclimate (UTCI)

How hot or cold does each outdoor place feel?

**≈ 31.1 °C** Between buildings **≈ 35.6 °C** Open park area

28 °C 38 °C

Hong Kong · perceived heat (UTCI)

Inputs

Weather, time period, buildings, trees, shade sails and canopies, and facade, roof and ground materials.

Output

UTCI in °C across an outdoor ground grid.

Results on

Ground Facades (no) Roofs (no) Rooms (no)

Method

UTCI (perceived temperature)

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-thermal-comfort-model-card.pdf)

## Sun, shade and sky

Sun hours, solar energy, sun access and open sky.

![Daylight Availability: Hong Kong · direct-sun availability score · August, 09:00–17:00](https://infrared.city/assets/models/daylight-availability-contrast-v4.webp)

### Daylight Availability

How reliably does direct sun reach this place during the selected window?

**≈ 60%** Between buildings **≈ 100%** Between buildings

0% 100%

Hong Kong · direct-sun availability score · August, 09:00–17:00

Inputs

Location, date and hour range, plus buildings, vegetation and terrain.

Output

Direct-sun availability from 0–100%.

Results on

Ground Facades Roofs Rooms (no)

Method

Ray-traced sun positions

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-sun-hours-daylight-model-card.pdf)

![Sky View Factors: Hong Kong · visible sky](https://infrared.city/assets/models/sky-view-factors-contrast-v4.webp)

### Sky View Factors

Where is the site open to the sky and where is it enclosed?

**≈ 18%** Between buildings **≈ 83%** Open park area

0% 100%

Hong Kong · visible sky

Inputs

Building geometry with optional vegetation, terrain or chosen surface sensors.

Output

Visible sky from 0–100%.

Results on

Ground Facades Roofs Rooms (no)

Method

Hemispherical ray trace

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-sky-view-factor-model-card.pdf)

![Direct Sun Hours: Hong Kong · cumulative direct sun](https://infrared.city/assets/models/direct-sun-hours-contrast-v4.webp)

### Direct Sun Hours

How long is each place in direct sun?

**≈ 88 h** Between buildings **≈ 270 h** Between buildings

0 h 279 h

Hong Kong · cumulative direct sun

Inputs

Location, date and hour range, plus buildings, vegetation and terrain.

Output

Hours of direct sun.

Results on

Ground Facades Roofs Rooms (no)

Method

Ray-traced sun positions

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-sun-hours-daylight-model-card.pdf)

![Solar Radiation: Hong Kong · façade and roof solar exposure](https://infrared.city/assets/models/facade-solar-contrast-v4.webp)

### Solar Radiation

Where does solar energy reach the site and building envelope?

0 kWh/m² 136 kWh/m²

Hong Kong · façade and roof solar exposure

Inputs

Weather radiation data, location, time range, buildings, trees and shade structures.

Output

Shortwave solar energy in kWh/m².

Results on

Ground Facades Roofs Rooms (no)

Method

Sun and sky model from weather data

[Playground](https://platform.infrared.city/sdk/playground) [Model card](https://infrared.city/assets/model-cards/infrared-solar-radiation-model-card.pdf)

## Room by room

Daylight and energy need inside the building.

![Interior Daylight Factor: Hong Kong tower · floor 37 · daylight factor · CIE overcast sky](https://infrared.city/assets/models/interior-daylight-factor-v4.webp)

### Interior Daylight Factor

How much diffuse daylight reaches this room under a standard overcast sky?

0% 10%+

Hong Kong tower · floor 37 · daylight factor · CIE overcast sky

Inputs

Room barriers, openings, work-plane sensors and optional external context.

Output

Daylight factor as a percentage at interior sensor points.

Results on

Ground (no) Facades (no) Roofs (no) Rooms

Method

CIE standard overcast sky

[Playground](https://platform.infrared.city/sdk/playground)

![Energy Balance: Eight rooms · annual cooling energy need per m² · Hong Kong weather, 2021](https://infrared.city/assets/models/energy-spatial-v5.webp)

### Energy Balance

How do envelope, solar gains and weather change heating and cooling demand?

Eight rooms · annual cooling energy need per m² · Hong Kong weather, 2021

Inputs

Spaces, barriers, openings, weather and energy settings.

Output

Heating and cooling need per room, per hour and per month, and annual kWh/m²·yr.

Results on

Ground (no) Facades (no) Roofs (no) Rooms

Method

ISO 13790 hourly method